fbpx

Local Reviews
for Reynoldsburg, OH

New Albany Heating & Cooling Rated 4.9 out of 5 stars based on 18 customer reviews

Map of Reynoldsburg, OH

5 Stars




Review of New Albany Heating & Cooling


Map of Reynoldsburg, OH

Great Service and Price!




Review of New Albany Heating & Cooling

The installation of the new furnace and A.C. went very smoothly and the HVAC installers were knowledgeable and efficient.


Map of Reynoldsburg, OH

Great service




Review of New Albany Heating & Cooling

They were very efficient and knowledgeable in the installation of the AC and furnace. They came out this month to check and adjust the AC for the warmer months to come as part of the installation fee.


Map of Reynoldsburg, OH

very pleased




Review of New Albany Heating & Cooling


Map of Reynoldsburg, OH

Great Service




Review of New Albany Heating & Cooling

Ben was our technician this morning to complete our cold season checkup as part of our maintenance contract. He was extremely polite and very professional. I am a technical person (not HVAC) and observed him while he worked. He took the time to answer my questions and explain the results. He did not push any products like some techs and we appreciate that. Based on this visit we will continue to use this company.


Map of Reynoldsburg, OH

Great Service




Review of New Albany Heating & Cooling

The technician was courteous and knowledgeable, he made repairs in a timely manner.


Map of Reynoldsburg, OH

Great Service!




Review of New Albany Heating & Cooling

We have had these folks for many years! They installed our current unit and do twice yearly check ups. They are always prompt, professional and the price is always fair. I would recommend them to anyone who wants good, quality ac/furnace/heat pump service. Their professionalism has made us long time customers and we will continue to use them!


Map of Reynoldsburg, OH

Incredible Service




Review of New Albany Heating & Cooling

The technician was quick to identify the problem and fix it quickly. I was really pleased with the speed of the remedy.


Map of Reynoldsburg, OH

Ac repair




Review of New Albany Heating & Cooling


Map of Reynoldsburg, OH

Great service on a Saturday! Fixed me up and at a good price




Review of New Albany Heating & Cooling

Great


Pooya Y.

Pooya Y.

Upon arrival for callback on 2017 Carrier furnace, furnace was not operational and showing led code 14 ignition failure. Noticed button on gas valve was in off position. Turned to on and cycled furnace through. Kicked on and went through heat cycle with no faults or errors. Continued to operate as intended for about 15 minutes while tech was present. System operational at departure.

Near Sanderling Dr, Reynoldsburg, OH 43068
Reynoldsburg, OH - Upon arrival for callback on 2017 Carrier furnace, furnace was not operational and showing led code 14 ignition failure. Noticed button on gas valve was in off position. Turned to on and cycled furnace through. Kicked on and went through heat cycle with no faults or errors. Continued to operate as intended for about 15 minutes while tech was present. System operational at departure.
Pooya Y.

Pooya Y.

Upon tune up safety check on 2000 Carrier furnace, flame sensor needed cleaned, also the exhaust pipe has rust spots on it and they are starting to form holes. Customer is wanting to get through this winter and replace the system next year and will get a hold of us when he is ready to do so. All other items checked out ok within manufacture specs at this time. System operational at departure.

Near Gummer Ct, Reynoldsburg, OH 43068
Reynoldsburg, OH - Upon tune up safety check on 2000 Carrier furnace, flame sensor needed cleaned, also the exhaust pipe has rust spots on it and they are starting to form holes. Customer is wanting to get through this winter and replace the system next year and will get a hold of us when he is ready to do so. All other items checked out ok within manufacture specs at this time. System operational at departure.
Pooya Y.

Pooya Y.

Upon arrival for a service call on 1996 Bryant furnace, showing led code 13 limit/rollout fault. After further diagnostic discovered that the rollout switch on draft is tripped. Reset switch and cycled system through heat cycle. System kicked on, took temp rise and it is at 61 degrees within range. Furnace is in rough shape has lots of rust on gas valve burners and also has hit spots on sides. Recommend furnace replacement due to current shape that it is in. Quoted customer for repairs as well. Furnace operational at departure.

Near Bennell Dr, Reynoldsburg, OH 43068
Reynoldsburg, OH - Upon arrival for a service call on 1996 Bryant furnace, showing led code 13 limit/rollout fault. After further diagnostic discovered that the rollout switch on draft is tripped. Reset switch and cycled system through heat cycle. System kicked on, took temp rise and it is at 61 degrees within range. Furnace is in rough shape has lots of rust on gas valve burners and also has hit spots on sides. Recommend furnace replacement due to current shape that it is in. Quoted customer for repairs as well. Furnace operational at departure.
Austin M.

Austin M.

I performed a tune up on a Carrier gas furnace. Everything checked out as it should. System is operational upon departure.

Near Hunnicut Dr, Reynoldsburg, OH 43068
Reynoldsburg, OH - I performed a tune up on a Carrier gas furnace. Everything checked out as it should. System is operational upon departure.
Randal S.

Randal S.

I performed a tune up on a Carrier gas furnace. Everything checked out within specs. System is operational upon departure.

Near Britwell Ln, Reynoldsburg, OH 43068
Reynoldsburg, OH - I performed a tune up on a Carrier gas furnace. Everything checked out within specs. System is operational upon departure.
Pooya Y.

Pooya Y.

Upon arrival, I discovered issue was not with inducer motor or pressure switch, but with the gas valve. I informed the customer of my findings and informed them we would be back out with a gas valve to install. System is not operational at departure due to gas valve not working.

Near Sunview Rd, Reynoldsburg, OH 43068
Reynoldsburg, OH - Upon arrival, I discovered issue was not with inducer motor or pressure switch, but with the gas valve. I informed the customer of my findings and informed them we would be back out with a gas valve to install. System is not operational at departure due to gas valve not working.
Randal S.

Randal S.

Upon arrival for service call on 1995 Goodman furnace, found system running as intended upon arrival. I tested system pull it was getting readings. Amp draws were within range. Cap on blower motor tested slightly out of spec. Flame sensor was reading low amps, I believe this was issue after checking everything else out and hearing customers description on what was happening so I pulled and cleaned flame sensor. It was reading higher amps now. I started system several times and everything came on fine. System had ran for 20 minutes prior to arrival with no issues as well.

Near Ives Ave, Reynoldsburg, OH 43068
Reynoldsburg, OH - Upon arrival for service call on 1995 Goodman furnace, found system running as intended upon arrival. I tested system pull it was getting readings. Amp draws were within range. Cap on blower motor tested slightly out of spec. Flame sensor was reading low amps, I believe this was issue after checking everything else out and hearing customers description on what was happening so I pulled and cleaned flame sensor. It was reading higher amps now. I started system several times and everything came on fine. System had ran for 20 minutes prior to arrival with no issues as well.
Austin M.

Austin M.

I replaced an in warranty OEM Direct Drive Blower Motor w/Capacitor and Cleaned Blower Motor on 2017 Carrier furnace (pictured below). Customer also purchased an iWave-R Air Purifier and Scheduled Maintenance Agreement with me.

Near Red Fox Rd, Reynoldsburg, OH 43068
Reynoldsburg, OH - I replaced an in warranty OEM Direct Drive Blower Motor w/Capacitor and Cleaned Blower Motor on 2017 Carrier furnace (pictured below). Customer also purchased an iWave-R Air Purifier and Scheduled Maintenance Agreement with me.
Austin M.

Austin M.

Upon arrival for tune up safety check on 2006 Rheem furnace, I went through furnace tune up list, everything checked out normally per routine maintenance. System is working within manufacturers specifications. System heating properly upon departure.

Near Lancaster Ave, Reynoldsburg, OH 43068
Reynoldsburg, OH - Upon arrival for tune up safety check on 2006 Rheem furnace, I went through furnace tune up list, everything checked out normally per routine maintenance. System is working within manufacturers specifications. System heating properly upon departure.
Austin M.

Austin M.

Upon arrival for tune up safety check on 2017 Carrier furnace, turned into diagnostic. Reset furnace from breaker, started furnace up. Furnace came on, blower motor was seized up. Recommended to customer blower cleaning and replacement of blower motor. Customer would like to move forward with those repairs as soon as possible. Furnace was operating and blowing heat upon departure.

Near Red Fox Rd, Reynoldsburg, OH 43068
Reynoldsburg, OH - Upon arrival for tune up safety check on 2017 Carrier furnace, turned into diagnostic. Reset furnace from breaker, started furnace up. Furnace came on, blower motor was seized up. Recommended to customer blower cleaning and replacement of blower motor. Customer would like to move forward with those repairs as soon as possible. Furnace was operating and blowing heat upon departure.