New Albany Heating & Cooling Rated 5.0 out of 5 stars based on 1 customer reviews

Map of Powell, OH

Great Service!




Review of New Albany Heating & Cooling

Great and friendly service!!!


Randal S.

Randal S.

I completed a diagnostic on a Carrier 16 SEER 3.5 Ton Air Conditioner. I determined that the system was wired up wrong, I corrected wiring and system was operational at time of departure.

Near Mallards Landing Dr, Powell, OH 43065
Powell, OH - I completed a diagnostic on a Carrier 16 SEER 3.5 Ton Air Conditioner. I determined that the system was wired up wrong, I corrected wiring and system was operational at time of departure.
Randal S.

Randal S.

I completed a diagnostic on a Trane Gas Furnace. I determined that system was displaying code 4 for open limit. High limit was stuck open. I was able to free high limit, changed the filter and system was operational at time of departure.

Near Coldwater Dr, Powell, OH 43065
Powell, OH - I completed a diagnostic on a Trane Gas Furnace. I determined that system was displaying code 4 for open limit. High limit was stuck open. I was able to free high limit, changed the filter and system was operational at time of departure.
Randal S.

Randal S.

I completed an installation inspection on a Carrier 16 Seer 4 Ton Air Conditioner. Completed installation checklist. Cycled and monitored the system. Operating normally at this time.

Near Tree Lake Blvd, Powell, OH 43065
Powell, OH - I completed an installation inspection on a Carrier 16 Seer 4 Ton Air Conditioner.  Completed installation checklist.  Cycled and monitored the system.  Operating normally at this time.
Pooya Y.

Pooya Y.

I returned with part for Humidifier pad and housing on a Honeywell Humidifier. System was operational at time of departure

Near Salisbury Dr, Powell, OH 43065
Powell, OH - I returned with part for Humidifier pad and housing on a Honeywell Humidifier. System was operational at time of departure
Pooya Y.

Pooya Y.

I completed a diagnostic on an a Honeywell Humidifier on a Carrier gas furnace. Determined that the housing the holds the pad is bad causing a leak. Shut off Humidifier and made customer aware that part needs ordered to repair.

Near Salisbury Dr, Powell, OH 43065
Powell, OH - I completed a diagnostic on an a Honeywell Humidifier on a Carrier gas furnace. Determined that the housing the holds the pad is bad causing a leak. Shut off Humidifier and made customer aware that part needs ordered to repair.
Randal S.

Randal S.

Upon arrival for callback on 2021 Five Star furnace, customer concerned about flashing yellow lights from unit. Found unit operating as intended, flashing light is heartbeat which is normal operation for this unit. Addressed customers other concerns. System operating as intended upon departure.

Near W Reindeer Dr, Powell, OH 43065
Powell, OH - Upon arrival for callback on 2021 Five Star furnace, customer concerned about flashing yellow lights from unit. Found unit operating as intended, flashing light is heartbeat which is normal operation for this unit. Addressed customers other concerns. System operating as intended upon departure.
Austin M.

Austin M.

Upon arrival for service call on 2018 Rheem furnace, furnace not lighting. Furnace circuit board was wired incorrectly using all 5 wires from AC to board instead of 2. Corrected the wiring and furnace is working and blowing hot air.

Near Clark-Shaw Rd, Powell, OH 43065
Powell, OH - Upon arrival for service call on 2018 Rheem furnace, furnace not lighting. Furnace circuit board was wired incorrectly using all 5 wires from AC to board instead of 2. Corrected the wiring and furnace is working and blowing hot air.
Bella  M.

Bella M.

Upon arrival for tune up safety check on 2007 Payne furnace, turned thermostat up 5 degrees from inside temperature for a call for heat. Visually inspected furnace condition and operation. Furnace return air filter was dirty and installed back wards. Removed front cover of furnace inside was a little dusty and dirty but not bad considering the age of everything. Inducer motor was in good condition with a good amp draw per manufacture specification. Burners were a little dusty but still allowing gas to flow through the way they were designed to. All limits and switches were operating normal. Gas pressure was good. Blower motor was operating normal with a good amp draw. Blower Capacitor tested out of spec, notified customer and replaced it. Combustion efficiency was good at 82.3% efficient on combustion. Put cover back on furnace double checked operation. System running normal. Customer also purchased iWave Air Cleaner through us and I installed.

Near Bierstad Dr, Powell, OH 43065
Powell, OH - Upon arrival for tune up safety check on 2007 Payne furnace, turned thermostat up 5 degrees from inside temperature for a call for heat. Visually inspected furnace condition and operation. Furnace return air filter was dirty and installed back wards. Removed front cover of furnace inside was a little dusty and dirty but not bad considering the age of everything. Inducer motor was in good condition with a good amp draw per manufacture specification. Burners were a little dusty but still allowing gas to flow through the way they were designed to. All limits and switches were operating normal. Gas pressure was good. Blower motor was operating normal with a good amp draw. Blower Capacitor tested out of spec, notified customer and replaced it. Combustion efficiency was good at 82.3% efficient on combustion. Put cover back on furnace double checked operation. System running normal. Customer also purchased iWave Air Cleaner through us and I installed.
Pooya Y.

Pooya Y.

Upon arrival for tune up safety check on 2020 Carrier furnace, humidifier water shut off valve was off turned on and checked humidifier all is ok. Customer also had concerns about the iWave air purifier, checked and it was installed on EAC terminal went ahead and wired up to L1 and neutral, tested air purifier and it is all good. All other items checked out good within manufacture specs at this time. System operational at departure.

Near Stream Isle Dr, Powell, OH 43065
Powell, OH - Upon arrival for tune up safety check on 2020 Carrier furnace, humidifier water shut off valve was off turned on and checked humidifier all is ok. Customer also had concerns about the iWave air purifier, checked and it was installed on EAC terminal went ahead and wired up to L1 and neutral, tested air purifier and it is all good. All other items checked out good within manufacture specs at this time. System operational at departure.
Pooya Y.

Pooya Y.

I provided an estimate for a Carrier 96% Two-Stage 100,000 BTU Gas Furnace and Carrier 17 SEER 2 STAGE 4 Ton Air Conditioner to replace customer's existing 2008 Trane gas furnace (pictured below) and AC.

Near Eventrail Dr, Powell, OH 43065
Powell, OH - I provided an estimate for a Carrier 96% Two-Stage 100,000 BTU Gas Furnace and Carrier 17 SEER 2 STAGE 4 Ton Air Conditioner to replace customer's existing 2008 Trane gas furnace (pictured below) and AC.