fbpx

Local Reviews
for Pataskala, OH

New Albany Heating & Cooling Rated 5.0 out of 5 stars based on 6 customer reviews

Map of Pataskala, OH

Great service




Review of New Albany Heating & Cooling


Map of Pataskala, OH

exceptional work




Review of New Albany Heating & Cooling

Isaiah was very professional and informative. He explained everything he was going to do and answered all my questions. He gave me recommendations for the future care of my HVAC system. I will certainly call New Albany Heating and Cooling in the future. Great job Isaiah!


Map of Pataskala, OH

Excellent service!




Review of New Albany Heating & Cooling

Bryan was pleasant and courteous while completing the most thorough inspection my system has ever had. He went above and beyond what was required, and I greatly appreciate it. I will request him for future service calls.


Map of Pataskala, OH

Very satisfied customer




Review of New Albany Heating & Cooling

If I ever need heating or cooling work done again, it will be through this company. The repairman came on time, fixed the problem, and even came back the same day to make sure it was fixed. The price was very reasonable.


Map of Pataskala, OH

Very Respectful




Review of New Albany Heating & Cooling

They showed up exactly when they said they were going to be. Very respectful and courteous. Answered all my question and very knowledgeable about HVAC.


Map of Pataskala, OH

Furnace check




Review of New Albany Heating & Cooling

Great service. Informative and thorough.


Randal S.

Randal S.

I replaced an in warranty furnace pressure switch on a 2016 Comfortmaker furnace,

Near Outville Rd SW, Pataskala, OH 43062
Pataskala, OH - I replaced an in warranty furnace pressure switch on a 2016 Comfortmaker furnace,
Randal S.

Randal S.

Tech found inducer motor on unit locked up, tech tried to free motor for temp heating. But was it unable to get it freed up, inducer motor will need replaced. Will contact office to order inducer motor.

Near Roscommon Dr, Pataskala, OH 43062
Pataskala, OH - Tech found inducer motor on unit locked up, tech tried to free motor for temp heating. But was it unable to get it freed up, inducer motor will need replaced. Will contact office to order inducer motor.
Randal S.

Randal S.

Upon arrival for a callback service on 2020 Carrier furnace, I found system was displaying previous code for limit fault or code 33. I addressed this issue by adjusting fan speed and changing out filter that was dirty. I also noticed thermostat head doesn't connect to the base plate very well. Notified customer of this. Also noticed large gap on back of filter box and furnace that had been taped the tape is falling off sheet metal work will most likely need done to fix this.

Near Sharon Heights Rd SW, Pataskala, OH 43062
Pataskala, OH - Upon arrival for a callback service on 2020 Carrier furnace, I found system was displaying previous code for limit fault or code 33. I addressed this issue by adjusting fan speed and changing out filter that was dirty. I also noticed thermostat head doesn't connect to the base plate very well. Notified customer of this. Also noticed large gap on back of filter box and furnace that had been taped the tape is falling off sheet metal work will most likely need done to fix this.
Bella  M.

Bella M.

Return service for a Nordyne heat pump with electric air handler. I replaced the capacitor. Cycled and monitored the system. Operating normally at this time.

Near Woodside Dr SW, Pataskala, OH 43062
Pataskala, OH - Return service for a Nordyne heat pump with electric air handler.  I replaced the capacitor.  Cycled and monitored the system.  Operating normally at this time.
Pooya Y.

Pooya Y.

I completed a diagnostic on a Bryant gas furnace. During diagnostic I discovered that most of the manufacture wiring harness has been replaced at some point NOT with manufacture specs wiring. All have been spliced in, found loose connection on spliced in inducer motor wires. Repaired short and got voltage to inducer, then determined that the igniter has failed. I gave and estimate to replace the ignitor. I recommend that due to the age (15 years), condition and cost of repairs that the unit be replaced. Client authorized replacement of ignitor. I replaced the ignitor. I informed the client that due to the wiring issues we will not be able to warranty any work performed today, Cycled and monitored the system. Operating normally at this time. Cycled and monitored the system. Operating normally at this time.

Near Carryback Dr SW, Pataskala, OH 43062
Pataskala, OH - I completed a diagnostic on a Bryant gas furnace.  During diagnostic I discovered that most of the manufacture wiring harness has been replaced at some point NOT with manufacture specs wiring.  All have been spliced in, found loose connection on spliced in inducer motor wires.  Repaired short and got voltage to inducer, then determined that the igniter has failed.  I gave and estimate to replace the ignitor.  I recommend that due to the age (15 years), condition and cost of repairs that the unit be replaced. Client authorized replacement of ignitor.  I replaced the ignitor.  I informed the client that due to the wiring issues we will not be able to warranty any work performed today,  Cycled and monitored the system.  Operating normally at this time.  Cycled and monitored the system.  Operating normally at this time.
Bella  M.

Bella M.

While performing tune up, dusted out indoor coil drain pan and furnace, tightened loose wire nuts, and moved blower capacitor to the front for easy maintenance in the future. Outdoor dual capacitor is low and will need replaced if customer is interested.

Near Woodside Dr SW, Pataskala, OH 43062
Pataskala, OH - While performing tune up, dusted out indoor coil drain pan and furnace, tightened loose wire nuts, and moved blower capacitor to the front for easy maintenance in the future. Outdoor dual capacitor is low and will need replaced if customer is interested.
Randal S.

Randal S.

I replaced PVC Exhaust Pipe Fitting and Installed Drain Boot for Carrier 96% Multi-Speed 60,000 BTU Gas Furnace.

Near Stonemast Loop, Pataskala, OH 43062
Pataskala, OH - I replaced PVC Exhaust Pipe Fitting and Installed Drain Boot for Carrier 96% Multi-Speed 60,000 BTU Gas Furnace.
Justina  P.

Justina P.

Filter was in backwards, turned filter around. Pulled and cleaned flame sensor. Inducer motor is going bad and will need to be replaced. Furnace is running at this time.

Near Keltonhurst Ct, Pataskala, OH 43062
Pataskala, OH - Filter was in backwards, turned filter around. Pulled and cleaned flame sensor. Inducer motor is going bad and will need to be replaced. Furnace is running at this time.
Pooya Y.

Pooya Y.

I performed a tune-up on a Carrier "Infinity Series" 98% Variable-Speed Modulating 80,000 BTU Gas Furnace. Found that inducer motor is louder than normal, I recommend replacing. All else is operating within manufacture specifications.

Near Millstone Cir, Pataskala, OH 43062
Pataskala, OH - I performed a tune-up on a Carrier "Infinity Series" 98% Variable-Speed Modulating 80,000 BTU Gas Furnace. Found that inducer motor is louder than normal, I recommend replacing. All else is operating within manufacture specifications.
Austin M.

Austin M.

I completed the service maintenance agreement fall tune up on a Carrier gas furnace. I visually inspected the unit. I cleaned the flame sensor. Checked voltages, amps and pressures. Completed combustion analysis. Cycled and monitored system. Operating normally at this time.

Near Trail E, Pataskala, OH 43062