I completed a fall tune up on a Carrier gas furnace. I visually inspected the unit. I cleared the condensate drain and cleaned the flame sensor. Checked voltages, amps and pressures. Completed combustion analysis. Cycled and monitored system. Operating normally at this time.

Near Crossing Creek Way, Gahanna, OH 43230
Gahanna, OH - I completed a fall tune up on a Carrier gas furnace.  I visually inspected the unit.  I cleared the condensate drain and cleaned the flame sensor. 
 Checked voltages, amps and pressures.  Completed combustion analysis.  Cycled and monitored system.  Operating normally at this time.
Pooya Y.

Pooya Y.

Upon arrival furnace was not operational, showing led code 3, pressure switch stuck open, Tested inducer motor and it is pulling 0.95inwc and pressure switch is rated to close at 0.60inwc enough to close switch, Bypassed switch and system kicked on operational normal, Also the door switch on furnace is broken, customer wanted switch bypassed and does not want to replace door switch at this time, Needs a new pressure switch, Furnace not operational at departure.

Near Little Pine Dr, Gahanna, OH 43230
Gahanna, OH - Upon arrival furnace was not operational, showing led code 3, pressure switch stuck open, Tested inducer motor and it is pulling 0.95inwc and pressure switch is rated to close at 0.60inwc enough to close switch, Bypassed switch and system kicked on operational normal, Also the door switch on furnace is broken, customer wanted switch bypassed and does not want to replace door switch at this time, Needs a new pressure switch, Furnace not operational at departure.
Jeffrey H.

Jeffrey H.

I performed a Install inspection to check to make sure the unit is running to the manufacturers recommendations

Near Shull Ave, Gahanna, OH 43230
Gahanna, OH - I  performed  a Install inspection to  check to make sure the unit is running to the manufacturers recommendations
Pooya Y.

Pooya Y.

Upon arrival the 2002 American standard Furnace was off at thermostat, Turned to heat, furnace kicked on and went through cycle, Tested flame sensor and getting 2.6ua it’s good within range, Inducer motor is pulling 1.3amps within range, Blower motor is pulling 5.7amps within range, Temp rise at 52 degrees within range, Filter is clean, Furnace continued to operate for about 25min with no faults/errors, Made customer aware that the service charge is good for 30 days and to give us a call if it starts acting up, Furnace operational at departure.

Near Pinegrove Pl, Gahanna, OH 43230
Gahanna, OH - Upon arrival  the 2002 American standard Furnace was off at thermostat, Turned to heat, furnace kicked on and went through cycle, Tested flame sensor and getting 2.6ua it’s good within range, Inducer motor is pulling 1.3amps within range, Blower motor is pulling 5.7amps within range, Temp rise at 52 degrees within range, Filter is clean, Furnace continued to operate for about 25min with no faults/errors, Made customer aware that the service charge is good for 30 days and to give us a call if it starts acting up, Furnace operational at departure.
Jeffrey H.

Jeffrey H.

I installed light switch on the 2003 Goodman Gas furnace in attic all ok at this time

Near Grove Dr, Gahanna, OH 43230
Gahanna, OH - I  installed light switch on the 2003 Goodman Gas furnace in attic all ok at this time
Pooya Y.

Pooya Y.

I am Performing our Five Star Tune-Up & Safety Check on a 2010 Carrier Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.

Near Moss Oak Ave, Gahanna, OH 43230
Pooya Y.

Pooya Y.

I am Performing our Five Star Tune-Up & Safety Check on a 2020 Carrier Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.

Near White Swan Ct, Gahanna, OH 43230
Gahanna, OH - 	I am Performing our Five Star Tune-Up & Safety Check on a 2020 Carrier  Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.
Pooya Y.

Pooya Y.

Performing our Five Star Tune-Up & Safety Check on a2006 Carrier . All readings were within manufacturer's specifications, unit operating properly at this time.

Near Jacob Cl, Gahanna, OH 43230
Gahanna, OH - Performing our Five Star Tune-Up & Safety Check on a2006 Carrier . All readings were within manufacturer's specifications, unit operating properly at this time.
Michael B.

Michael B.

Found ground wire on Amana AC from high voltage whip touching one 120V leg of of supply voltage. Moved ground wire away from high voltage and secured. System operating properly at this time.

Near N Stygler Rd, Gahanna, OH 43230
Gahanna, OH - Found ground wire on Amana AC from high voltage whip touching one 120V leg of of supply voltage. Moved ground wire away from high voltage and secured. System operating properly at this time.
Pooya Y.

Pooya Y.

Found faulty compressor on Payne AC. Customer is purchasing new Carrier AC.

Near Lyncroft Dr, Gahanna, OH 43230
Gahanna, OH - Found faulty compressor on Payne AC. Customer is purchasing new Carrier AC.