New Albany Heating & Cooling Rated 4.9 out of 5 stars based on 8 customer reviews

Map of Canal Winchester, OH

Perfect




Review of New Albany Heating & Cooling

Carl was wonderful. Great guy, great service! I'm a very happy customer.


Map of Canal Winchester, OH

Great Service Always




Review of New Albany Heating & Cooling

I always request Carl S. for my service twice a year for my maintenance on my a/c and furnace. He is very respectful and thorough. He always takes the time to explain everything and offer helpful tips. I would highly recommend the company and Carl S. It is most important to have people you can trust!


Map of Canal Winchester, OH

All around A+




Review of New Albany Heating & Cooling

Calling for service on a 15 year old furnace I was apprehensive but ended up pleasantly surprised by the economical price and efficient service!


Map of Canal Winchester, OH

Great, friendly service




Review of New Albany Heating & Cooling

Carl was prompt, cheerful and skilled, quickly diagnosing and correcting the problem with my furnace.


Map of Canal Winchester, OH

Awesome service by Carl and James




Review of New Albany Heating & Cooling

These two guys were amazing, very nice and helpful. Great with communication, and informational.


Map of Canal Winchester, OH

Great service, professional. I believe, though, he was from Canal Winchester Heating and Cooling.




Review of New Albany Heating & Cooling

He was able to detect the problem with ease, very polite and honest. Obviously enjoys his work. Very nice demeanor.


Map of Canal Winchester, OH

Above Average Service




Review of New Albany Heating & Cooling


Map of Canal Winchester, OH

Great




Review of New Albany Heating & Cooling

Great


Michael B.

Michael B.

Found a gas valve leak on Goodman furnace. May replace gas valve or replace the furnace in the fall.

Near Lehman Rd, Canal Winchester, OH 43110
Canal Winchester, OH - Found a gas valve leak on Goodman furnace. May replace gas valve or replace the furnace in the fall.
Randal S.

Randal S.

Found faulty TXV on Carrier AC. Part has been ordered and will return to install upon arrival.

Near Woody Ct, Canal Winchester, OH 43110
Canal Winchester, OH - Found faulty TXV on Carrier AC. Part has been ordered and will return to install upon arrival.
Randal S.

Randal S.

Replaced high voltage surge capacitor on Rheem AC. System cooling properly at this time.

Near Greensview Village Dr, Canal Winchester, OH 43110
Randal S.

Randal S.

Tuneup and safety check on Goodman AC. All checks are good at this time.

Near Buckner St, Canal Winchester, OH 43110
Canal Winchester, OH - Tuneup and safety check on Goodman AC. All checks are good at this time.
Randal S.

Randal S.

Tuneup and safety check on Carrier AC. All is working properly at this time. Customer received military discount.

Near Porter Dr, Canal Winchester, OH 43110
Canal Winchester, OH - Tuneup and safety check on Carrier AC. All is working properly at this time. Customer received military discount.
Randal S.

Randal S.

Replaced high voltage surge capacitor on customer AC. System cooling properly at this time.

Near Canal Highlands Blvd, Canal Winchester, OH 43110
Canal Winchester, OH - Replaced high voltage surge capacitor on customer AC. System cooling properly at this time.
Michael B.

Michael B.

I Found common wire from compressor burnt off common terminal at capacitor, Common side is melted/damaged. Capacitor needs replaced, also wiring needs repaired. Replaced capacitor and cleaned up wiring on the 2004 Comfortmaker.

Near Village Grove Ln, Canal Winchester, OH 43110
Canal Winchester, OH - I Found common wire from compressor burnt off common terminal at capacitor, Common side is melted/damaged. Capacitor needs replaced, also wiring needs repaired. Replaced capacitor and cleaned up wiring on the 2004 Comfortmaker.
Michael B.

Michael B.

Customer states when the 2006 Trane system is not working both blower and Ac won’t run- leads me to believe problem is between thermostat and control board at furnace. Previous thermostat did not need batteries it is hard wired into board. Customer had a new ECOBEE installed, but they still had a “no cool” situation- wiring looks good and installed correctly. Did find low voltage plug at furnace control board not all the way seated, seated correctly and ac does not fault while here(it’s possible this was the issue, also possible user error with new thermostat)

Near Gender Rd, Canal Winchester, OH 43110
Canal Winchester, OH - Customer states when the 2006 Trane system is not working both blower and Ac won’t run- leads me to believe problem is between thermostat and control board at furnace. Previous thermostat did not need batteries it is hard wired into board. Customer had a new ECOBEE installed, but they still had a “no cool” situation- wiring looks good and installed correctly. Did find low voltage plug at furnace control board not all the way seated, seated correctly and ac does not fault while here(it’s possible this was the issue, also possible user error with new thermostat)
Pooya Y.

Pooya Y.

Upon arrival found condenser fan motor is burned up, Due to age of system and cost of repairs, replacing the OEM Condenser Fan Motor and Capacitor, customer is doing a new system install, System not operational at departure.

Near Berry Pond Ct, Canal Winchester, OH 43110
Canal Winchester, OH - Upon arrival found condenser fan motor is burned up, Due to age of system and cost of repairs, replacing the OEM Condenser Fan Motor and Capacitor, customer is doing a new system install, System not operational at departure.
Michael B.

Michael B.

Found water around furnace area found dirty filter. When blower starts up, noise is heard indicating start windings failure of blower motor.Told customer before I cleaned motor that motor will not be used to the Torque it will now generate with it being clean and could fail at any time, customer still wanted me to clean blower. Blower is original to the 25 years old Lennox System .

Near Warriner Way, Canal Winchester, OH 43110
Canal Winchester, OH - Found water around furnace area found dirty filter. When blower starts up, noise is heard indicating start windings failure of blower motor.Told customer before I cleaned motor that motor will not be used to the Torque it will now generate with it being clean and could fail at any time, customer still wanted me to clean blower. Blower is original to the 25 years old Lennox System .